Изберете език

Xgard Bright

Производител: Crowcon
Xgard Bright UL Certificate
Xgard Bright IECEx Certificate
Xgard Bright ATEX Certificate
Xgard Bright CCS Type Approval
Xgard Bright ECAS Certificate
Xgard Bright PESO Certificate
Xgard Bright HART Certificate
Xgard Bright Datasheet
Xgard Bright Manual Multilingual

Available with MPS™ technology to eliminate risk of poisoning and need for calibration, the Xgard Bright is the next generation of multi-gas detection. This fixed detector offers flammable and toxic gas detection and oxygen monitoring, combined with reduced installation costs and ease of operation.

Xgard Bright is a versatile detector offering flammable and toxic gas detection and oxygen monitoring, while providing ease of operation and reduced installation costs.

Choose from durable sensor options to suit your needs, such as MPS (10+ years), Long-life O2 (5 years) and IR sensors (10+ years) to prevent frequent sensor replacements and minimise operational expenses.

Lowering the cost of installation, the 4-wire addressable implementation drastically reduces cabling requirements. The large OLED display allows users to easily work with Xgard Bright during install, calibration and routine maintenance without the need to open the housing.

Providing analogue 4-20mA and RS-485 Modbus signals as standard, Xgard Bright comes with an Alarm and Fault relay as standard as well as optional HART communications.

  • MPS™ sensor available
  • Low installation cost
  • Easy operation
  • 4-20mA and RS-485 Modbus signals
  • Alarm and Fault relay

Next Generation Sensor Technology

  • MPS™ (Molecular Property Spectrometer) technology
  • TrueLEL™ multi-gas accuracy
  • Free from risk of sensor poisoning
  • No calibration or scheduled maintenance is needed
  • Hydrogen ready

Versatile

  • Available in both high-grade aluminium alloy or 316 stainless steel
  • Flammable and toxic gas detection, as well as oxygen monitoring options
  • Choose from MPS™, Long-Life O2 and IR sensor options, all with long lifespans
  • Choice of M20 or ½”NPT connection to suit your specific site requirements
  • Low power usages (~3W max) helping reduce site-wide power consumption
  • IP65 or IP66 rating (with weatherproof cap), allowing for use in areas subject to regular wash downs or in exposed environments

Ease of Installation & Operation

  • Addressable operation reduces the amount of cabling needed for multi-point installations
  • Local display delivers gas level indication and device status at a glance
  • Non-intrusive calibration eradicates the need to open the cover for calibration
  • Plug in type terminal blocks for reduced installation costs
  • Configuration via magnetic key helps minimise the amount of time operators spend in a hazardous area
Size

Aluminium enclosure:

ATEX/IECEx: 156 x 166 x 109 mm (6.1 x 6.5 x 4.3 inch)

UL: 162 x 166 x 110 mm (6.4 x 6.5 x 4.3 inch)

Stainless Steel Enclosure:

ATEX/IECEx: 165 x 166 x 105 mm (6.1 x 6.5 x 4.1 inch)

UL: 162 x 166 x 103 mm (6.4 x 6.5 x 4.1 inch)

Cable Gland Entry 2x M20 or 2x ½” NPT (Stopping plug fitted to the left-side entry)
Operating Voltage 12-30Vdc.
Power 3W max
Electrical Output 3-wire 4-20mA (Sink or Source)
RS-485 Modbus RTU
HART 7 (Optional)
Weight

Aluminium enclosure:

ATEX/IECEx: 1kg (2.2 lbs)

UL: 1.5 kg (3.31 lbs)

Stainless Steel Enclosure:

ATEX/IECEx: 3.1 kg (6.8 lbs)

UL: 3.5 kg (7.72 lbs)

Enclosure Material ADC 12 aluminium alloy or 316 stainless steel
Relay Alarm 1, Alarm 2, Fault (SPDT Contacts. Rated 1A, 24Vdc)
Sounder Out High Side Switch (24V nominal, 12V minimum, 700mA maximum load)
Operating Temperature

ATEX/IECEx: -40°C to +70°C (-40°F to 158°F)

UL: -40°C to +60°C (-40°F to 140°F)

Humidity

0 to 95% RH, non-condensing

Contact Crowcon for sensor operating humidity range.

Repeatability +/- 2% FSD
Zero drift +/- 2% FSD per year maximum
Ingress protection IP65/66, EN 60529
Hazloc Standards & Approvals

ATEX: EN IEC 60079-0, EN 60079-1, EN 60079-31

IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-31

Zone 1 and Zone 2 or Zone 21 and Zone 22

Aluminium:

Ex II 2 G Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C

Ex II 2 D Ex tb IIIC T80°C Db

Ex db IIC T6 Gb Tamb: -40°C≤Ta≤70 °C

Ex tb IIIC T80°C Db

Stainless Steel:

Ex II 2 G Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70 °C

Ex II 2 G Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C

Ex II 2 D Ex tb IIIC T80°C Db

Ex db IIC T3 Gb Tamb: -40°C≤Ta≤70°C

Ex db IIC T4 Gb Tamb: -40°C≤Ta≤50°C

Ex tb IIIC T80°C Db

UL: UL 1203

-40°C≤Ta≤60 °C

Class I, Division 1, Groups B, C, D T6

Class II Division 1, Groups E, F, G T6

Approvals

UL, IECEx, ATEX, CE, ECAS, PESO, CNEx, UC, CCSA TA, MED***

EMC Compliance EN 50270, EN IEC 61326-1, EN 55011, CISPR 11, EN 61000-4
Performance UL 60079-29-1***
Zones Certified for use in Zone 1 and Zone 2 areas
Warranty

2 years on transmitter

5 years on MPS flammable and O2 Long Life sensor

2 years on IR flammable sensors

Refer to GEN067 – Warranty Periods

for other sensors

***Contact Crowcon for availability

Gas Sensor type Gas range Temp
range °C 
Flammable gases* MPS 0-100% LEL -40 to +75
Butane (C4H10) Infrared 0-100% LEL -40 to +60
Hydrogen (H2) Catalytic 0-100% LEL -40 to +70
LPG

Catalytic

Infrared

0-100% LEL

-40 to +70

-40 to +60

Methane (CH4)

Catalytic

Infrared

0-100% LEL

0-100% LEL

-40 to +70

-40 to +60

Pentane (C5H12)

Catalytic

Infrared

0-100% LEL

0-100% LEL

-40 to +70

-40 to +60

Propane (C3H8)

Catalytic

Infrared***

0-100% LEL

0-100% LEL

-40 to +70

-40 to +60

Carbon Monoxide (CO) Electrochemical 0-25, 50, 100, 200, 250, 300, 1000, 2000 ppm -30 to +50
Hydrogen Sulphide (H2S) Electrochemical 10, 20, 25, 50, 100, 200 ppm -40 to +50
Oxygen (O2) Long Life (Lead free) Electrochemical 0-25% vol -40 to +60
Oxygen (O2) Electrochemical 0-25% vol -20 to +50
Carbon Dioxide (CO2) Infrared 0-5% vol -40 to +60

* Contact Crowcon for more information

Copyright MAXXmarketing GmbH
JoomShopping Download & Support