Изберете език

XgardIQ

Производител: Crowcon
XgardIQ IECEx Certificate
XgardIQ ATEX Certificate
XgardIQ EU Declaration of Conformity
XgardIQ SIL Certificate
XgardIQ Performance Certificate – EN 50271, EN 50104, EN 45544
XgardIQ Performance Report – EN 60079-29-1, IEC 60079-29-1
XgardIQ INMETRO Certificate
XgardIQ ECAS-Ex Certificate
XgardIQ PESO Certificate
XgardIQ HART Certificate
XgardIQ Datasheet
XgardIQ Full Manual

The XgardIQ is our most intelligent fixed gas detector, increasing safety by minimising the time operators must spend in hazardous areas.

This versatile SIL2 certified gas detector and transmitter has a range of features that protect people in oil, gas, chemical & petrochemical plants to name just a few.

Available fitted with a variety of sensors for flammable, toxic, oxygen or fixed H2S gas detection.

XgardIQ is an intelligent and versatile fixed detector and transmitter. Its remote sensor and universal transmitter means you have access to Crowcon’s full range of sensor technologies and improved detection. With its sensor range selection capabilities it means users can set the full-scale range of the sensor according to specific location requirements.

Available fitted with a variety of sensors for fixed flammable, toxic, oxygen or H2S gas detection, this SIL2 certified detector is easy and safe to use, with OLED display for easy visibility of reading even in dark locations and a +Ve safety indicator to quickly confirm the detector is operating soundly at a glance.

The XgardIQ is optionally available with Alarm and Fault relays and HART communications.

  • Auto-sense & auto-configure function
  • Universal transmitter
  • +Ve safety indicator
  • Non-intrusive calibration
  • Remote sensor

Easy & Safe to Use

  • OLED display for bright, clear gas level indication and detector status even in dark locations
  • Non-intrusive calibration removing the need for a hot-work permit or any special tools
  • Positive Safety indicator confirms the detector is operating safely at a glance
  • Event log function stores all alarm, fault and maintenance events to provide a history of detector use
  • Remote sensor for improved probability of detection

Simple Installation & Maintenance

  • Universal transmitter compatible with Crowcon’s full range of sensor technologies
  • Simple sensor replacement can be done single-handedly
  • Auto-sense function automatically detects whether the control system is 4-20mA current sink or source and sets itself appropriately, eliminating the risk of being incorrectly set
  • Auto-configure function detects when a sensor module is plugged-in and uploads the appropriate gas type, range, units and alarm levels

Reliable

  • Smart Bump and Speedy Bump test functions for quick sensor-health verification and automated reminders
  • Calibration reminders to ensure that sensors remain operational and accurate at all times
  • User can set the full-scale range of the sensor via the display menu according to site or specific location requirements
Size H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in)
Weight 4.1Kg (9lbs)
Enclosure material 316 stainless steel
Ingress protection IP66
Connection Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries
Power 14-30 VDC. <4W
Display Main display – OLED 128 x 64 pixels, yellow text on black background
Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED
Electrical output 4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant
RS-485 Modbus RTU
HART 7 over 4-20mA signal and via local I.S. test points (optional)
Relays (optional)
Alarm 1, Alarm 2, Fault
SPCO contacts rated 5A, 230Vac
Relay configuration options
Energised or de-energised
Latching or non-latching
Rising or falling
Configurable On and Off delays on alarm relays.
Event logging Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC.
Operating temperature Transmitter only: -40°C to +75°C (-40°F to +167°F)†

 

Sensor type:

Oxygen: (-20°C to +50°C ambient)
Toxic: (-40°C to +50°C ambient)
Pellister: (-40°C to +75°C ambient)
Infra-red (IR): (-20°C to +55°C ambient)
High temperature toxic:  (-40⁰C to +70⁰C)

Humidity 0 to 95% RH non-condensing†
Repeatability +/- 2% FSD
Zero drift +/- 2% FSD per year maximum
Response time Sensor dependant: contact Crowcon for specific sensor data.
Approvals ATEX and IECEx:
Ex II 2 G    Ex db ia IIC T4 Gb (see above for temperature ranges)
Performance Designed for compliance with:
EN50104 (oxygen sensors)
EN45544 (toxic gas sensors)*
EN50271 (software)
H2S performance standard
Functional safety IEC61508, EN50402 SIL 2
EMC Compliance EN50270:2015
FCC CFR47 Part 15B
ICES-003
Gas Units Max
Range
Standard
Range
Alarm 1
level
Alarm 2
level
Temp
range °C 
Oxygen (O2) %Vol 30 25 19 (falling) 17 (falling) -20 to +50
Ammonia PPM 100/1000 50 25 35 -20 to +40
 Carbon Monoxide (CO) PPM 1000 250 30 200  -30 to +50
Hydrogen Fluoride (HF) PPM 10 10 1.8 3 +5 to +40
Hydrogen Sulphide (H2S) PPM 100/200 25 5 10 -30 to +50
High Temperature Hydrogen Sulphide (H2S) PPM 100/200 25 5 10 -40 to +70
Ozone (O3) PPM 1 1 0.1 0.2 -20 to +40
Sulphur Dioxide (SO2) PPM 100 10 1 1 -30 to +50
Hydrogen (H2) %LEL 100 100 20 40 -40 to +75
Methane (CH4) %LEL 100 100 20 40 -40 to +75
Pentane (C5H12) %LEL 100 100 20 40 -40 to +75
Propane (C3H8) %LEL 100 100 20 40 -40 to +75
Ethanol (IR sensor) %LEL 100 100 20 40 -20 to +55
LPG (IR sensor) %LEL 100 100 20 40 -20 to +55
Methane (IR sensor) %LEL 100 100 20 40 -20 to +55
Propane (IR sensor) %LEL 100 100 20 40 +10 to + 55
Copyright MAXXmarketing GmbH
JoomShopping Download & Support