Select your language

IRmax

Manufacturer: Crowcon
ATEX Certificate (Auxiliary Junction Box)
ATEX Certificate (Spigot gland)
IECEx Certificate (Spigot gland)
SIL Certificate IRmax
ATEX Certificate Issue 6 – IRMAX (no display)
ATEX Certificate Issue 7 – IRMAX (with display)
IECEx Certificate Issue 7 – IRMAX (no display)
IECEx Certificate Issue 8 – IRMAX (with display)
IECEx Certificate (Auxiliary Junction Box)
IRmax Datasheet
IRmax Manual – Multi language (Issue 7 May 2021)

IRmax is a compact, low power and highly rugged infrared (IR) gas detector, that delivers rapid, fail-safe detection of methane, butane, propane and many other hydrocarbon gases and vapours. The IRmax infrared gas detection system offers the choice of a detector only, a local gas/status display, a remote gas/status display or non-intrusive calibration via an I.S. calibration tool or hand-held HART communicator.

Dependability in all conditions is what makes the IRmax stand out from the crowd, with the reliability of the IRmax hydrocarbon detector proven in hot, cold, wet and saline environments.

IRmax’s unique Stay-ClIR optical components are treated with a highly durable coating that completely prevents faults due to condensation, making it ideal for offshore use.

Certified for use in Zone 1 & 2 and EMC compliant*, the IRmax is compatible with virtually any control system, requiring minimal routine maintenance helping keep costs at a minimum. The IRmax also contains no components for artificially heating optical surfaces, meaning power consumption is dramatically reduced, requiring only 1W of power.

The remote display can be mounted up to 30 metres from the IRmax and test gas can be applied without requiring direct access to the detector. It can also be wall mounted, fitted to a 50mm (2 inch) pipe or connected to an auxiliary junction box, making it a reliable and versatile choice for hydrocarbon gas detection.

*Directive 2014/30 EU: EN50270, FCC CFR47 Part 15B, ICES-003

  • Simple to install
  • Easy maintenance
  • Low cost of ownership
  • Ideal for offshore use
  • IR dependability

Simple to Install

  • Its compact size requires less space, effort and time to install
  • Can be wall mounted, fitted to a 50mm (2 inch) pipe, or connected to an auxiliary junction box using a choice of mounting accessories
  • Industry standard 4-20mA output is compatible with virtually any control system
  • Options for HART communications and RS-485 Modbus

Easy Maintenance

  • Remote non-intrusive calibration means the remote display can be mounted up to 30 metres from the IRmax, and test gas applied without requiring direct access to the detector
  • Fitted with an I.S barrier module, the device can be checked and calibrated using an I.S handheld display
  • STAY-CLIR optics prevents condensation on optical components, for clear readings at all times

Low Cost of Ownership

  • Only consumes 1W of power, meaning small power supplies and battery back-up systems can be used
  • Minimal routine maintenance keeps costs down
  • Annual proof-test interval
  IRmax IRmax with Fixed IR display IRmax with IS Barrier Module Remote IR Display
Size 158 x 75 x 57mm (6.2 x 2.9 x 2.3ins) 230 x 75 x 57mm (9 x 2.9 x 2.3ins) 261 x 75 x 57mm (2.3 x 2.9 x 2.3ins) 60 x 54 x 48mm (2.3 x 2.1 x 1.9ins)
Weight 1.58kg (3.5lbs) 2kg (4.4lbs) 2.4kg (5.3lbs) 0.2kg (0.4lbs)
Ingress protection IP66
Enclosure material 316 stainless steel
Power 12-30 Vdc. < 1W
Connection One M20 or 1/2” NPT cable gland entry
Electrical output 4-20mA current sink or source
2mA dirty optics warning (at 75% obscuration, configurable)
0mA detector fault signal (at 90% obscuration, configurable)
RS-485 Modbus (optional), HART 7 (optional)
Operating temperature -40°C to +75°C (-40°F to 167°F)
Humidity 0 to 95% RH non-condensing
Pressure range Atmospheric +/- 10%
Repeatability +/- 2% FSD
Zero drift +/- 2% FSD per year maximum
Response time T-90 <4 seconds
Functional safety Validation to IEC61508, EN50402 SIL 2
Approvals Ex II 2 GD
Exd IIC T6 Gb (Tamb -40to+50°C),
T4 (Tamb -40to+75°C)
Ex tb IIIC T135°C Db (Tamb -40 to +75°C)
Ex II 2 G
Exd ia IIC T4 Gb (Tamb -40to+75°C)
  Ex II 2 GD
Exd ia IIC T4 Gb (Tamb -40to+75°C)
Ex tb IIIC T135°C Db (Tamb -40 to +40°C)
EMC compliance Directive 2014/30 EU: EN50270, FCC CFR47 Part 15B, ICES-003
Zones Certified for use in Zone 1 & 2.
Copyright MAXXmarketing GmbH
JoomShopping Download & Support